search

Not finding what
you need?

Call Gasco: 1-877-427-7347

INSTRUMENTS

PIC Gauges
    • Ashcroft 1490 Low Pressure Diaphragm Gauge

      Ashcroft 1490 Low Pressure Diaphragm Gauge

      The Ashcroft® Type 1490 low pressure diaphragm gauge is designed to measure
      pressure from 10 in. H2O to 15 psi, both positive and negative pressures. This
      gauge uses a very sensitive diaphragm capsule to measure low pressure and
      vacuum.
      The gauge is specifically designed for use whenever the pressure
      medium is a gas that is not corrosive to beryllium copper, brass, polysulfone and
      RTV silicone. The polysulfone case is suitable for intermittent or continuous
      service on natural gas provided a .013 throttle plug is installed in the socket.
      Typical applications are, but not limited to, vacuum pumps, gas leak detectors, air
      compressors, air filters, gas burners, gas measurement, vacuum ovens, suction
      regulators and respirators.


      • Sensus Regulator 496 : 3/8″, 1/2″, 3/4″, and 1″

        Sensus Regulator 496 : 3/8″, 1/2″, 3/4″, and 1″

        Available Sizes
        Regular: 3/8", 1/2", 3/4", and 1"

        Diaphragm: 4" Molded, roll-out polyester fabric reinforced Buna-N with integral relief seat and case flange seal
        Vent and Valve: Precision-fit polypropylene valve and seat, threaded 3/4" or 1" NPT
        Adjustment Screw: ABS cycolac
        Closing Cap: ABS cycolac with internal relief valve stop and a hole for available tamper seal wire
        Corrosion Protection: Chromate converted castings, topcoat enamel,optional E-coat
        Internal Relief Valve: Set to relieve at 7" w.c. - 10" w.c. above normal outlet pressure setting of 7" w.c.

        For use on other compatible gases, flow capacities must be adjusted using the following correction factors:
        Type Gas Sp Grav Corr Factor
        Air 1.0 0.77
        Propane 1.53 0.63
        Propane-air 1.2 0.71
        Nitrogen 0.97 0.79
        Dry CO2 1.52 0.63

        For other non-corrosive gases, the Correction Factor is equal to: √0.6/Specific Gravity

        Mounting Positions
        These are multi-poised regulators, designed to that they can be mounted in any piping orientation.

      • Low Capacity

        Low Capacity

        Available Models:
        30051-1XS: 1/2” NPT
        30052-2XS: 3/4” NPT
        30053-3XS: 1” NPT

        Pietro Fiorentini's Governor line of gas regulators are designed to comply with the latest CSA and International standards for regulators suitable for indoor or outdoor installations with no modifications.

        The Governor family of regulators are ideal for all burner installations and for low pressure gas distribution systems. The materials and soft parts used in the construction of the Governor regulators makes them suitable for use with natural gas, LPG, Propane air and all other non corrosive gases.

        All the Governor regulators are equipped with balanced valve design for high outlet pressure accuracy regardless of any inlet pressure variation. The double diaphragm provides added security in case of primary diaphragm failure. The integral vent limiter eliminates the need for costly piping for indoor installations and complies with CSA guidelines. The number of regulator options sometimes eliminates the need for separate units and significantly reduced installation cost.

      • Sensus Regulator 143-80-1 : 3/4″, 1″, 1-1/4″

        Sensus Regulator 143-80-1 : 3/4″, 1″, 1-1/4″

        Sensus residential service regulators have a simple, modern design and rugged construction, offering greater dependability, precise pressure control, and outstanding performance. These are multi-poised regulators, designed to that they can be mounted in any piping orientation. The union nut style connection of the 143-80 makes it especially easy to adjust.

        Diaphragm: Nylon fabric reinforced Buna-N with full 26 in2 effective area

        Vent and Valve: Precision-fit polyethylene valve and seat, threaded 3/4", 1", 1=1/4" NPT

        Corrosion Protection: Cases dip primed chromate conversion coating, topcoat enamel

        Internal Relief Valve: none

      • UE J402K-456-1520 Differential Pressure Switch, Electro-Mechanical

        UE J402K-456-1520 Differential Pressure Switch, Electro-Mechanical

        Pressure, Vacuum, Differential Pressure
        AND Temperature SWITCHES

        features
        • 1, 2 & 3 switch outputs
        • Epoxy-coated enclosure designed
        to meet enclosure type 4X
        • Wide variety of pressure sensors and
        materials
        • Setting via reference dial or hex
        screw adjustment
        • FM approved
        • Adjustable Ranges:
        "WC ranges: 300 "wc vacuum to 250 “wc
        pressure (-746,7 to 622,3 mbar)
        Pressure: 30 “Hg Vac to 6000 psi
        (-1,0 to 413,7 bar)
        Differential pressure: 1"wcd to 200 psid
        (2.5 mbar to 13,8 bar)
        Temperature: -180 to 650 °F
        (-117.8 to 343.3 °C)

      • Sensus Regulator 143-80-2 : 3/4″, 1″, 1-1/4″

        Sensus Regulator 143-80-2 : 3/4″, 1″, 1-1/4″

        Sensus residential service regulators have a simple, modern design and rugged construction, offering greater dependability, precise pressure control, and outstanding performance. These are multi-poised regulators, designed to that they can be mounted in any piping orientation. The union nut style connection of the 143-80 makes it especially easy to adjust.

        Diaphragm: Nylon fabric reinforced Buna-N with full 26 in2 effective area

        Vent and Valve: Precision-fit polyethylene valve and seat, threaded 3/4", 1", 1=1/4" NPT

        Corrosion Protection: Cases dip primed chromate conversion coating, topcoat enamel

        Internal Relief Valve: Set to relieve at approximately 7" w.c. above normal outlet pressure setting

      • UE J402K-455-1520 Differential Pressure Switch, Electro-Mechanical

        UE J402K-455-1520 Differential Pressure Switch, Electro-Mechanical

        The UE 400 Series differential pressure switches offer solutions for applications which require single or multiple switching capabilities. Dual and triple switch versions provide multi-output for alarm and shutdown, pre-alarm and alarm, high/low limit or level staging functions. An ideal choice for most ordinary location applications, the 400 Series provides threshold protection and control for many critical functions in installations found in industrial gas production; energy generation including pumps, turbines and compressors; pulp and paper; and water and wastewater treatment.

        • 1, 2 and 3 switch output
        • Epoxy-coated 4X enclosure
        • Setting via reference dial or hex screw
        • Adjustable pressure ranges from 1"wcd to 200 psid


      KEP
        • LCN4X Remote Display Enclosure

          LCN4X Remote Display Enclosure

          Low Cost NEMA 4X Housing for 1/8 and 1/16 DIN Size Units

          FEATURES:
          • Made of impact and corrosive resistant VELOX®,
          RAL 7035
          • Molded internal bosses for back panel,
          component mounting and DIN-rails
          • NEMA4X / IP66 Rating
          • UL 508 and CSA Type 4, 4X, 3, 3R, 12, 13 Rating
          • Temperature resistance: Base and opaque cover
          to +248ºF (120ºC) per UL 746B. Polycarbonate
          cover -40ºF (40ºC) to +248º (120ºC)
          • Non-Metallic cover screws
          • Continuously poured polyurethane gasket
          • Cover and bases meet with tongue and groove
          design for tight seal

          Options:
          H2 - 0.875” Hole for Hub fi tting
          HF2 - 0.5” Female NPT Hub fi tting
          2H2 - Two 0.875” Holes for Hub fi ttings
          2HF2 - Two 0.5” Female NPT Hub fi ttings
          H3 - Three 0.84” Holes for Hub fi ttings

        • ES651MRTA3 Remote Display w/ 4/20 mA Output

          ES651MRTA3 Remote Display w/ 4/20 mA Output

          Features
          • Separate Scaling Factors For A & B Inputs
          • Display Rate & Total
          • Pulse Input- 10 kHz Max.
          • RS422/RS232 Serial Communication (optional)
          • Modbus RTU RS422/RS485/RS232 (optional)
          • NEMA 4X / IP65 Front Panel
          • Separate Add/Subtract Simultaneous Inputs
          • Quadrature and Up/Down Direction Control Inputs (optional)
          • 30mV Magnetic Pickup Inputs (optional)

        • ES651MRTA3 Remote Display

          ES651MRTA3 Remote Display

          Features
          • Separate Scaling Factors For A & B Inputs
          • Display Rate & Total
          • Pulse Input- 10 kHz Max.
          • RS422/RS232 Serial Communication (optional)
          • Modbus RTU RS422/RS485/RS232 (optional)
          • NEMA 4X / IP65 Front Panel
          • Separate Add/Subtract Simultaneous Inputs
          • Quadrature and Up/Down Direction Control Inputs (optional)
          • 30mV Magnetic Pickup Inputs (optional)


            • Remote Consumption Display Riotronics

              Remote Consumption Display Riotronics

              RIO Tronics' LCD 9305 - Outdoor Remote Consumption Display

              Features:
              - Direct connect to all types of RIO Tronics' pulse output products, or any digital output
              - Outdoor mountable - all components designed for -20 C to 120 C
              - Displays reading of electric, gas or water meter remotely
              - Scalable for reads in 100s of cubic feet or gas meter remotes
              - NEMA 4 rated, your notes on label are protected
              - Test pulse output devices from RIO Tronics
              - 15 year replaceable lithium battery
              - Wall mount through drillable corners
              - Five digits, overall size 3.5" x 3.5" x 2.4"


              UE
              • UE J402K-456-1520 Differential Pressure Switch, Electro-Mechanical

                UE J402K-456-1520 Differential Pressure Switch, Electro-Mechanical

                Pressure, Vacuum, Differential Pressure
                AND Temperature SWITCHES

                features
                • 1, 2 & 3 switch outputs
                • Epoxy-coated enclosure designed
                to meet enclosure type 4X
                • Wide variety of pressure sensors and
                materials
                • Setting via reference dial or hex
                screw adjustment
                • FM approved
                • Adjustable Ranges:
                "WC ranges: 300 "wc vacuum to 250 “wc
                pressure (-746,7 to 622,3 mbar)
                Pressure: 30 “Hg Vac to 6000 psi
                (-1,0 to 413,7 bar)
                Differential pressure: 1"wcd to 200 psid
                (2.5 mbar to 13,8 bar)
                Temperature: -180 to 650 °F
                (-117.8 to 343.3 °C)

              • UE J402K-455-1520 Differential Pressure Switch, Electro-Mechanical

                UE J402K-455-1520 Differential Pressure Switch, Electro-Mechanical

                The UE 400 Series differential pressure switches offer solutions for applications which require single or multiple switching capabilities. Dual and triple switch versions provide multi-output for alarm and shutdown, pre-alarm and alarm, high/low limit or level staging functions. An ideal choice for most ordinary location applications, the 400 Series provides threshold protection and control for many critical functions in installations found in industrial gas production; energy generation including pumps, turbines and compressors; pulp and paper; and water and wastewater treatment.

                • 1, 2 and 3 switch output
                • Epoxy-coated 4X enclosure
                • Setting via reference dial or hex screw
                • Adjustable pressure ranges from 1"wcd to 200 psid

              • UE J402-525  10″ – 250″ WC Pressure Switch NEMA 1

                UE J402-525 10″ – 250″ WC Pressure Switch NEMA 1

                Pressure, Vacuum, Differential Pressure
                AND Temperature SWITCHES

                features
                • 1, 2 & 3 switch outputs
                • Epoxy-coated enclosure designed
                to meet enclosure type 4X
                • Wide variety of pressure sensors and
                materials
                • Setting via reference dial or hex
                screw adjustment
                • FM approved
                • Adjustable Ranges:
                "WC ranges: 300 "wc vacuum to 250 “wc
                pressure (-746,7 to 622,3 mbar)
                Pressure: 30 “Hg Vac to 6000 psi
                (-1,0 to 413,7 bar)
                Differential pressure: 1"wcd to 200 psid
                (2.5 mbar to 13,8 bar)
                Temperature: -180 to 650 °F
                (-117.8 to 343.3 °C)

              • UE J402-443 0″ – 80″ WC Pressure Switch NEMA1 Enclosure

                UE J402-443 0″ – 80″ WC Pressure Switch NEMA1 Enclosure

                The UE 400 Series pressure and vacuum switches offer solutions for applications which require single or multiple switching capabilities. Dual and triple switch versions provide multi-output for alarm and shutdown, pre-alarm and alarm, high/low limit or level staging functions. An ideal choice for most ordinary location applications, the 400 Series provides threshold protection and control for many critical functions in installations found in industrial gas production; energy generation including pumps, turbines and compressors; pulp and paper; and water and wastewater treatment.

                • 1, 2 and 3 switch output
                • Epoxy-coated 4X enclosure
                • Setting via reference dial or hex screw
                • Adjustable pressure ranges from vacuum to 6000 psi

              • UE J402-442  0″ – 20″ WC Pressure Switch NEMA 1

                UE J402-442 0″ – 20″ WC Pressure Switch NEMA 1

                Pressure, Vacuum, Differential Pressure
                AND Temperature SWITCHES

                features
                • 1, 2 & 3 switch outputs
                • Epoxy-coated enclosure designed
                to meet enclosure type 4X
                • Wide variety of pressure sensors and
                materials
                • Setting via reference dial or hex
                screw adjustment
                • FM approved
                • Adjustable Ranges:
                "WC ranges: 300 "wc vacuum to 250 “wc
                pressure (-746,7 to 622,3 mbar)
                Pressure: 30 “Hg Vac to 6000 psi
                (-1,0 to 413,7 bar)
                Differential pressure: 1"wcd to 200 psid
                (2.5 mbar to 13,8 bar)
                Temperature: -180 to 650 °F
                (-117.8 to 343.3 °C)

              • UE J402-441  0″ – 10″ WC Pressure Switch NEMA1

                UE J402-441 0″ – 10″ WC Pressure Switch NEMA1

                Pressure, Vacuum, Differential Pressure
                AND Temperature SWITCHES

                features
                • 1, 2 & 3 switch outputs
                • Epoxy-coated enclosure designed
                to meet enclosure type 4X
                • Wide variety of pressure sensors and
                materials
                • Setting via reference dial or hex
                screw adjustment
                • FM approved
                • Adjustable Ranges:
                "WC ranges: 300 "wc vacuum to 250 “wc
                pressure (-746,7 to 622,3 mbar)
                Pressure: 30 “Hg Vac to 6000 psi
                (-1,0 to 413,7 bar)
                Differential pressure: 1"wcd to 200 psid
                (2.5 mbar to 13,8 bar)
                Temperature: -180 to 650 °F
                (-117.8 to 343.3 °C)