GE Dresser Meters

GE Dresser Meters
  • 8C175 CTR : Series A

    8C175 CTR : Series A

    Available Models:
    8C175 CTR

    Features
    • Lightweight Aluminum
    Construction
    • Rugged Hard Coated Cylinder,
    Headplates and Impellers
    • Compact Size
    • Multi-position Mounting
    • 175 PSIG (1200kPa) Working Pressure
    • Low Maintenance
    • Long Service-life
    • Simple Installation: 1-1/2” NPT
    Male Connections
    • Available in English and Metric

    Model 8C175 ROOTS Meter
    The 8C175 CTR ROOTS Meter is the smallest, lightest and most versatile rotary gas meterever produced. Permanent accuracy, rugged construction, wide rangeability and
    simple field testing add up to the best investment in gas measurement equipment your
    company can make.

    All units are subjected to rigorous hydrostatic, leak, starting and running differential tests.
    Accuracy and differential data are furnished for 100% and 10% of rated capacity from
    positive displacement bell provers

  • 8C175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    8C175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    Available Models:
    • 8C175 CTR
    • 8C175TC
    • 8C175ICPWS
    • 8C175ITPWS
    • 8C175ICEX

    Features:
    • Lightweight Aluminum
    Construction
    • Rugged Hard Coated Cylinder,
    Headplates and Impellers
    • Compact Size
    • Multi-position Mounting
    • 175 PSIG (1200kPa) Working Pressure
    • Low Maintenance
    • Long Service-life
    • Simple Installation: 1-1/2” NPT
    Male Connections
    • Available in English and Metric

    All units are subjected to rigorous hydrostatic, leak, starting and running differential tests.
    Accuracy and differential data are furnished for 100% and 10% of rated capacity from
    positive displacement bell provers

  • 15C175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    15C175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    Available Models:
    • 15C175 CTR
    • 15C175TC
    • 15C175ICPWS
    • 15C175ITPWS
    • 15C175ICEX

    The ROOTS meter Series B3 is a positive displacement, rotary type gas meter
    designed for continuously measuring and indicating the accurate measurement of
    gas in a pipeline. ROOTS meters are suitable for handling most types of clean,
    dry, common gases at either constant or varying flow rates. Meters of standard
    construction are not directly suitable for handling acetylene, biogas or sewage gas.
    Contact the factory for information on specially constructed meters made of
    materials directly compatible with these and other gases.

  • 2M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    2M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    Available Models:
    • 2M175 CTR
    • 2M175 TC
    • 2M175 ICPWS
    • 2M175 ITPWS
    • 2M175 ICEX

    Series B3 meters are designed to provide accurate gas measurement over widely fluctuating flow, pressure, and temperature conditions. For further versatility, the five smallest meter sizes (8C through 3M) have 2” (50 mm) flanged connections and a 6-3/4” (171 mm) flange-to-flange dimension. If application requirements change, this unique, cost-effective feature allows a quick and easy meter exchange without the need to re-pipe the meter set.

    Capacity ratings from 800 CFH to 56,000 CFH (22,6 m3/h to 1,585 m3/h)
    Maximum operating pressure rating of 175 PSIG (12 Bar)
    Models 8C through 5M are available with a 200 PSIG (13,8 Bar) rating upon request
    Models 8C through 2M are available with a 1-1/2” nippled connections upon request
    Operating temperature range from -40°F to +140°F (-40°C to +60°C)

  • 3M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    3M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    Available Models:
    • 3M175 CTR
    • 3M175 TC
    • 3M175 ICPWS
    • 3M175 ITPWS
    • 3M175 ICEX

    Series B3 meters are designed to provide accurate gas measurement over widely fluctuating flow, pressure, and temperature conditions. For further versatility, the five smallest meter sizes (8C through 3M) have 2” (50 mm) flanged connections and a 6-3/4” (171 mm) flange-to-flange dimension. If application requirements change, this unique, cost-effective feature allows a quick and easy meter exchange without the need to re-pipe the meter set.

    Capacity ratings from 800 CFH to 56,000 CFH (22,6 m3/h to 1,585 m3/h)
    Maximum operating pressure rating of 175 PSIG (12 Bar)
    Models 8C through 5M are available with a 200 PSIG (13,8 Bar) rating upon request
    Models 8C through 2M are available with a 1-1/2” nippled connections upon request
    Operating temperature range from -40°F to +140°F (-40°C to +60°C)

  • 5M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    5M175 CTR, TC, ICPWS, ITPWS, and ICEX : Series B

    Available Models:
    • 5M175 CTR
    • 5M175 TC
    • 5M175 ICPWS
    • 5M175 ITPWS
    • 5M175 ICEX

    Series B3 meters are designed to provide accurate gas measurement over widely fluctuating flow, pressure, and temperature conditions. For further versatility, the five smallest meter sizes (8C through 3M) have 2” (50 mm) flanged connections and a 6-3/4” (171 mm) flange-to-flange dimension. If application requirements change, this unique, cost-effective feature allows a quick and easy meter exchange without the need to re-pipe the meter set.

    Capacity ratings from 800 CFH to 56,000 CFH (22,6 m3/h to 1,585 m3/h)
    Maximum operating pressure rating of 175 PSIG (12 Bar)
    Models 8C through 5M are available with a 200 PSIG (13,8 Bar) rating upon request
    Models 8C through 2M are available with a 1-1/2” nippled connections upon request
    Operating temperature range from -40°F to +140°F (-40°C to +60°C)